SynchroGrid developed relay settings for transformer protection, bus protection, and feeder protection as well as providing relay coordination for the transformer and distribution feeder at a local substation.
The process involved the following:
SynchroGrid provided relay settings and GOOSE messaging review along with quality control for Cross Texas Transmission's Railhead reactor additions.
SynchroGrid provided relay settings and GOOSE messaging review along with quality control for Cross Texas Transmission's Gray to Allen Creek line additions.
SynchroGrid provided relay settings and GOOSE messaging review along with quality control for Cross Texas Transmission's Gray shunt reactor upgrades.
SynchroGrid provided an analysis of the operation of a 345kV bus trip.
SynchroGrid provided relay settings services for the entire 138 : 12.47kV Substation.
SynchroGrid provided relay setting and relay coordination services for a local substation.
SynchroGrid provided relay setting development services to upgrade two retrofit transformer panels.
SynchroGrid developed extensive relay settings as well as relay coordination for a local substation.
SynchroGrid upgraded SEL 487E-0 Reactor relays with SEL-487E-3 relays.
SynchroGrid replaced GE-T60 reactor relays with SEL-387E relays and upgraded SEL 487E-0 reactor relays with SEL-487E-3 relays.
SynchroGrid provided a relay settings review for the ERCOT Region. This was for ERCOT RARF 5.4.
SynchroGrid provided relay setting and relay coordination services for a local substation.
SynchroGrid provided relay setting development services for a local substation.
SynchroGrid performed an arc flash analysis on the electrical distribution system for South Kent Wind Farm - a wind farm operated by Pattern Energy.
SynchroGrid performed an arc flash analysis on the electrical distribution system for a wind farm operated by Pattern Energy.
SynchroGrid developed relay settings and provided relay coordination services for a local substation.
SynchroGrid provided relay settings for a local substation.
SynchroGrid provided quality system protection services in developing settings for a number of local terminals including Enterprise, TAMU, and Dowling terminals.
This project consisted of verifying the adequacy and reliability of new features and settings along with existing settings within the firmware upgrade.
SynchroGrid provided quality relay setting development services by creating new settings for relays at five substations for a Texas utility.